FLX800­™ Series FLX34/FLX54

Category: Golf sprinklers
Application: Golf

The New FLEX800™ 34/54 Series with dual trajectory main nozzle provides exceptional nozzle performance at the 25° standard angle position and great performance in windy applications at the 15° low angle position. And the consistency of the constant velocity full circle drive ensures even water application across the coverage area every time you water.

Dual Trajectory - 25° or 15°
  • Provides two selections for the main nozzle trajectory; the 25 degree setting provides maximum distance of throw and the 15 degree setting provides improved wind performance, radius reduction and obstacle avoidance.
Industry's Largest Nozzle Selection

Nozzles from 15.8 – 30.5m plus a wide assortment of back nozzles lets you put the precise amount of water exactly where you need it. All nozzles threaded in from front.

Stainless Steel Valve Seat

Eliminates body damage from rocks and debris. This indestructible stainless steel seat is moulded to the body and virtually eliminates body replacements due to seat damage.

Optional Radius Reduction Screw

Allows for fine tuning the radius to exactly the distance you need. In combination with main nozzle sizing and trajectory adjustment, the radius reduction screw can effectively reduce the sprinkler throw to 9.1m.

Constant Velocity Full-circle Drive

Ensures consistent rotation speeds when matched with station run times for even water application across the coverage area, every time you water.

Operating Specifications

  • Inlet:
    • FLX34: 25mm (1″) ACME
    • FLX54: 40mm (1.5″) ACME
  • Radius:
    • FLX34: 15.8 – 27.7 m
    • FLX54: 15.8 – 30.2 m
  • Flow Rate:
    • FLX34: 48.8 – 177.5 Lpm
    • FLX54: 50.0 – 233.9 Lpm
  • Precipitation Rates:
    • FLX34:
      • Minimum: 8.4 mm/hr
      • Maximum: 14.0 mm/hr
    • FLX54:
      • Minimum: 8.4 mm/hr
      • Maximum: 15.5 mm/hr
  • Pilot Valve:
    • Fixed pressure at 65 and 80 psi
  • Recommended Operating Pressure:
    • 65 – 100 psi
    • Maximum: 150 psi
    • Minimum: 40 psi

Electrical Specifications:

  • Standard Solenoid:
    • 24 VAC, 50/60 Hz
    • Inrush: 0.30 A
    • Holding: 0.20 A
  • Spike Guard Solenoid:
    • 24 VAC, 50/60 Hz
    • Inrush: 0.12 A
    • Holding: 0.10 A
  • Nickel-Plated Spike Guard Solenoid:
    • 24 VAC, 50/60 Hz
    • Inrush: 0.12 A
    • Holding: 0.10 A
  • DC Latching Solenoid:
    • 12 VDC pulse or latching pulse
  • Integrated GDC Module w / DCL
    • 12 VDC pulse or latching pulse

 